Technical data
Model | RJ-350R/SN2 | RJ-500R/SN2 |
Power supply
| 380-420V 3~ 50Hz | 380-420V 3~ 50Hz |
Application air temp. range °C | -5 - 45 | -5 - 45 |
Air 27°C /Water 27 °C | Heating capacity W | 30,744 | 52,680 |
COP | 5.2 | 5.1 |
Air 15°C /Water 26 °C | Heating capacity W | 27,300 | 43,890 |
COP | 4.95
| 4.75
|
Air 35°C /Water 27 °C | Cooling capacity W | 23,150 | 33,700 |
EER | 2.88 | 2.75 |
Refrigerant
| Type | R410A | R410A |
Fan motor | Air flow rate m3/h | 7,000*2 | 7,000*2 |
Rotating speed rpm | 800 | 800 |
Hydraulic connection | G2" / PVC flexible connection | G 2" / flexible connection |
Unit | Dimensions WxDxH mm | 1450 x 702 x 950 | 1450 x 702 x 950 |
| Net weight kg | 236 | 268 |
Packing | Dimensions WxDxH mm | 1525 x 805 x 1110 | 1525 x 805 x 1110 |
| Net weight kg | 279 | 316 |
Product Features
Various capacities for commercial application
√ Heating capacity from 20kW up to 250kW
√ For commercial purpose of application
Titanium tube-shell condenser
√ Titannium tube in plastic shell condenser
√ Totally rust-free water loop
High efficiency, energy conservation
√ High efficiency, pool heating wilth lowest energy bill
Smart wifi control (optional)
√ Control your heat pump all by your mobile phone
√ Minitor the running state of your heat pump at anytime